| Manufacturer Name | EATON CONTROLS (CUTLER-HAMMER) |
| MfgPartNo | MD34E79B |
| Additional Information | APPROVAL UL 506, UL 1561; APPLICABLE STANDARD ANSI C89.2, NEMA ST-20 |
| Application | Commercial / Institutional Buildings / Structures - Safety and Security Systems;AC/DC ADJUSTABLE SPEED DRIVE, INDOOR/OUTDOOR |
| Base Price | 0.0000 |
| Brand Name | EATON[R] |
| Catalog Number | MD34E79B |
| Commerce Sector | Construction Materials |
| Commodity Code | 39172 |
| Commodity Description | Three Phase Drive Isolation & Auto Dry Type Transformers 600v Or Less |
| Construction | VENTILATED, DRIP PROOF |
| CountryOfOrigin | MX |
| DDCATEGORY | 2076 |
| Design | DT-3 |
| Dimensions | 22.0000 IN X 29.0000 IN X 39.0000 IN |
| Directory | CIS |
| Enclosure | NEMA 2 |
| Families | 2076 |
| Family Description | Three Phase Drive Isolation & Auto Dry Type Transformers 600v Or Less |
| Frequency | 60 Hz |
| Image Location | * Image |
| Industry | ELX |
| InvoiceDescription | 34KVA VENT'D DR ISOL 480D-480Y/277 80C;34KVA TFM |
| Item Number | 05753 |
| Long Description | MOTOR DRIVE ISOLATION TRANSFORMER, DT3 TYPE; 23 INCH W X 16.5 INCH D X 30 INCH H SIZE; 3 PHASE(S); AC/DC ADJUSTABLE SPEED DRIVE, INDOOR/OUTDOOR APPLICATION; NEMA 2 ENCLOSURE; VENTILATED, DRIP PROOF CONSTRUCTION; 34 KVA POWER RATING |
| MSDS Form Number | * |
| Model | MD |
| Noun | * |
| Number Of Phases | 3 |
| Power Rating | 34 KVA |
| Power Rating In KVA | 34 |
| Primary Voltage | 480 V DELTA AT 60 HZ |
| Primary Voltage 1 Maximum | 480 V |
| Primary Voltage 1 Minimum | 480 V |
| Primary Voltage 2 Maximum | 480 V |
| Primary Voltage 2 Minimum | 480 V |
| Primary Voltage 3 Maximum | 480 V |
| Primary Voltage 3 Minimum | 480 V |
| Product Description | 34KVA TFM |
| Product Keywords | WEBREADY |
| Product Name | Isolation transformer |
| ProductLine | C-H |
| Secondary Voltage | 480 V STAR/277 V AT 60 HZ |
| Secondary Voltage 1 Maximum | 480Y/277 V |
| Secondary Voltage 1 Minimum | 480Y/277 V |
| Secondary Voltage 2 Maximum | 480Y/277 V |
| Secondary Voltage 2 Minimum | 480Y/277 V |
| Secondary Voltage 3 Maximum | 480Y/277 V |
| Secondary Voltage 3 Minimum | 480Y/277 V |
| Size | 23 INCH W X 16.5 INCH D X 30 INCH H |
| Standard | UL Listed |
| Tap Size | 1 at +5% FCAN, 1 at -5% FCBN |
| Taps | (1) +5 PERCENT X (1) -5 PERCENT |
| Temperature Rating Maximum | 176 F |
| Temperature Rating Minimum | 176 F |
| Temperature Rise | 80 DEG C |
| Type | Ventilated transformer;DT3 |
| UNSPSC | 39121029 |
| UPC | 78668005753 |
| Vendor Name | EATON TFMRS & DISTRIB |
| Vendor Number | 786680 |
| Vendor Short Name | CHX |
| Winding Type | ALUMINUM |